EMSGLOB — Test Probes & Test Fixture Solutions Request Free Quote

High-Current Contact Probes

FK-048 High-current Probe

FK-048 is a high-current probe series in the EMSGLOB range. It suits a minimum pitch of 35 mm / 1377,95 mil, is 115.5 mm long overall and offers 7 mm of working travel.

Electrically it is specified for a rated current of 400 A, a typical resistance of 0.1 mΩ and an operating range of -55 °C to +80 °C. It is ordered as part number FK-048.

FK-048 high-current probe – product view

Specifications

Minimum pitch35 mm / 1377,95 mil
Total length115.5 mm
Installation height35 mm
Rated travel7 mm
Max. travel11 mm
Rated current400 A
Typical resistance0.1 mΩ
Operating temperature-55 °C to +80 °C

Values as listed for this series. Confirm the exact data for your part number with your quotation.

Applications

  • Power electronics and inverter testing
  • Battery cell, module and pack contacting
  • Testing of plug connectors and charging interfaces
  • End-of-line and burn-in stations that need high continuous current
FK-048 high-current probe – dimension drawing
Dimension drawing

Part numbers (1)

Part numberTip / head styleHead Ø (mm)Spring force (N)
FK-048Stepped (code 03)29.9100

FAQ

What pitch and length is FK-048?

FK-048 has a minimum pitch of 35 mm / 1377,95 mil, total length of 115.5 mm and installation height of 35 mm. The full dimension list is in the specification table on this page.

How much current can FK-048 carry?

The rated continuous current is 400 A, with a typical resistance of 0.1 mΩ.

What temperature range is FK-048 rated for?

FK-048 is specified for -55 °C to +80 °C.

How do I get a price or sample for FK-048?

Send the part number, quantity and your application to sales@emsglob.com or call +91-7383235369, or use the enquiry form on the contact page. Prices are quoted per enquiry.

More high-current contact probes

Enquire / Request a quote

Tell us the FK-048 part number, the quantity and your pitch, travel and current requirements, and the EMSGLOB team will reply with availability and a quotation. Drawings in STEP, IGES, PDF, DWG, DXF or ZIP are welcome.